5.1.4 Evolution of the Interface Group of MIB-II From RFC 1573
MIBs for generic objects for network Interface sub-layers ‘ifMIB’ 1.3.6.1.2.1.31
MIB Objects ‘ifMIBObjects’ 1.3.6.1.2.1.31.1
Extension to the Interface Table ‘ifXTable’ 1.3.6.1.2.1.31.1.1
oid = “1.3.6.1.2.1.31.1.1.1.1.ifIndex”
ifName: the textual name of the interface.
Access: read-only
oid = “1.3.6.1.2.1.31.1.1.1.2.ifIndex”
ifInMulticastPkts: the number of multicast packets received, 32 bit.
Access: read-only
oid = “1.3.6.1.2.1.31.1.1.1.3.ifIndex”
ifInBroadcastPkts: the number of broadcast packets received, 32 bit.
Access: read-only
oid = “1.3.6.1.2.1.31.1.1.1.4.ifIndex”
ifOutMulticastPkts: the number of multicast packets transmitted, 32 bit.
Access: read-only
oid = “1.3.6.1.2.1.31.1.1.1.5.ifIndex”
ifOutBroadcastPkts: the number of broadcast packets transmitted, 32 bit.
Access: read-only
oid = “1.3.6.1.2.1.31.1.1.1.6.ifIndex”
ifHCInOctets: the total number of octets received on the interface, 64 bit.
Access: read-only
oid = “1.3.6.1.2.1.31.1.1.1.10.ifIndex”
ifHCOutOctets: the total number of octets transmitted by the interface, 64 bit.
Access: read-only
oid = “1.3.6.1.2.1.31.1.1.1.14.ifIndex”
ifLinkUpDownTrapEnable: indicates whether or not linkup/linkDown traps should be
generated for this interface.
1 = enabled
2 = disabled
Access: read-write
oid = “1.3.6.1.2.1.31.1.1.1.15.ifIndex”
ifHighSpeed: an estimate of the interface current bandwidth in units of 1M bits/sec.
Access: read-only
oid = “1.3.6.1.2.1.31.1.1.1.16.ifIndex”
ifPromiscuousMode: indicates whether this interface only accepts packets/frames
addressed to this station (false) or accepts all packets/frames transmitted on the media
(true). The value does not affect broadcast and multicast packets/frames.
1 = true
2 = false
Access: read-only
oid = “1.3.6.1.2.1.31.1.1.1.17.ifIndex”
ifConnectorPresent: indicates whether the interface has a physical connector.
1 = true
2 = false
Access: read-only